Order Code:CV3110-HY-A1061-F10-H1100-M2-N10-T20-K1085-K144-P9-W4019 PRESSURE TRANSMITTER PASCAL CV standard process connections for food/pharmaceutical/biotechnology acc. to data sheet D4-017/22 CV3110 surface roughness: hygienic version pressure sensor: piezoresistive for gauge pressure nominal range: 40 bar, overload limit 100 bar measuring range setting: turndown 5:1 accuracy: <= 0.15% of measuring span (linearity, hysteresis and repeatability) measuring range: 0...40.00 bar output signal: 4...20 mA, rising characteristic (standard) setting damping: 0.0 sec. (standard) setting alarm state: < 3.6 mA display module: multifunctional display with 5-position digital display and bar graph, pluggable switching module: without case: hygienic housing design with screw cap material: stainless steel degree of protection: IP 66 electrical connection: cable gland M 16 x 1.5, PA black design standard process connection: clamp connection per DIN 32676, DN 25 material stainless steel mat.-no. 1.4404/1.4435 (316L) system filling: foodstuff oil FD1, acc. to FDA approval class USDA-H1 process temperature see below -10...+125°C short term 140°C 1h delivery time: stock |