Order Code: CE6120-A1011.1-K1014.1-T120-H1

CE6 COMPACT PRESSURE TRANSMITTER with threaded connection

see data sheet D4-020-1

12 design: flush mounted diaphragm, with temperature decoupler

0 Ex-protection: without

A1 pressure sensor: piezoresistive for gauge pressure

011.1 measuring range 0...400 mbar, overload limit 20 bar

measuring accuracy:

linearity error incl. hysteresis < + 0.2 % f.s.

accuracy of adjustment < +/- 0.2 % f.s.

temperature effect Tk < 0.4% / 10K

K10 process connection: threaded connection

14 nominal width: G1 B with O-ring and sealing washer

.1 gasket material: EPDM in correspondence with FDA

T120 electrical connection: circular connector M12, IP 65, union nut of

polyamide

H1 output signal: 4...20 mA, 2-wire technology

Country of origin:Germany

Custom-Tariff-No.: 90262020