• Turbine meter Vision® 3000

Turbine meter Vision® 3000

for low viscous, non aggressive liquids and low flow rates

 

  • DN12
  • Largest measuring range
  • Trogamid
  • High operating pressure
  • NSF, WRAS
Medium:
Water, Chemical/Petrochemical media, Liquid food, Pharmaceutical media, Others
max. flow:
from 5 up to 65 l/min
max. pressure:
from 0 up to 25 bar
Branch:
Water & waste water industry, Chemical industry, General industry, Food & beverage industry, Aerospace industry, Pharmaceutical industry, Automotive industry

 

General information

The liquid turbine meters of the series Vision® 3000 are for the exact measuring of small quantities of liquids. The actual flow as well as the already passed flow can be measured.

 

Technical data

Material Trogamid
Viscosity range 0,8 – 16 mm²/s
Accuracy ±3 % of value
Repeatability < 0,5 %
Temperature range -20 °C up to +100 °C
Operating pressure 25 bar max.
Electrical connection Electrical connector EN 60529 or cable connection
Power supply 5 – 24 VDC
Output signal Open collector NPN pulse
Process connections G ¾“, NPT ¾“
Approvals KTW, NSF, WRAS

 

Measuring principle

Turbine meters


Turbine meters

Turbine meters are volumetric meters. When the fluid passes through, a rotor is activated and the movement is either electronically or mechanically transmitted outside.