General information
The meter has been designed to measure flow of antifreeze, water-based and other lightly aggressive media with a viscosity of 8 to 2000 mPas. The meter housing as well as the innerparts are special coated, the outlet is out of stainless steel. Type LM OG-PND-DC measures flow within 1 to 30 l/min range in liters, quarts, pints or gallons and can preselect up to 5 dispense quantities. With an accuracy of +/- 0.5%, it measures within a pressure range of 0,35 to 65 bars at temperatures between -5°C to +50°C.
The user can programm the preset meter (preselection and free dispense) and choose the measuring unit. A 5-digit LCD display with a resolution of 0,005 l shows the dispensed quantity. The meter is operated with four exchangeable AA batteries, is calibrated in the factory but can also be calibrated on site if desired. The meter is light-weighted, has an ergonomical grip, ½” BSPP connections and protection class IP42.
Thanks to its rugged construction, the meter can be used in the workshop as well as in the industry.
Technical data
Connection | ½“ BSP |
Max. operating pressure | 100 bar |
Flow range | 1 – 35 l/min |
Temperature range | -10 °C up to +50 °C |
Accuracy | ±0,5 % |
Viscosity range | up to 5000 mPas |
Protection class | IP 67 |
Display | 6-digit LCD display |
Calibration | can be calibrated |