• Blancett® QuickSert® Gas B142

Blancett® QuickSert® Gas B142



 

  • Reliable
  • Light weight
Medium:
Gas
max. flow:
from 190 up to 9832 l/min
Temperature:
from -40 up to 165 °C
max. pressure:
from 0 up to 150 bar
Branch:
Oil industry, Gas industry

 

Technical data

Material Housing: 316 L stainless steel
  Rotor: 410/304 stainless steel
  Bearings: Tungsten carbide
Measuring range 7 – 350 ACFM
Size 2"
Flow accuracy ±2 % of reading over the specified measuring range
Repeatability ±0,5 %
Calilbration -
Pressure ratings* Vacuum 15.3 mPa max.
Operating temperature -40 °C up to +165 °C
End connections Wafer-style, ASME/ANSI B16.5 – 1996
Approvals Class I Div 1, Groups C, D; Complies to UL 913 and CSA 22.2 Nr. 157-92
   
* depending of the end connections  
 

 

Measuring principle

Turbine meters


Turbine meters

Turbine meters are volumetric meters. When the fluid passes through, a rotor is activated and the movement is either electronically or mechanically transmitted outside.